Özet:
As an offshore energy producing unit, it moves to deeper waters. The foundation design demand requires more creativity and a complex approach, especially for large turbines (approximately 5 to 7 MW). In this text, an alternative pile with double-walled piles in close distances to each other at the corners of the jacket has been studied for piles of various dimensions and sizes. A numerical parametric study was conducted to investigate the effects of pile spacing and pile length on their behavior with the protected system under combined uniform loads in very dense sand. Before the analysis, the numerical model was validated in the context of testing single and double piles; generally, the contribution of the near-field space of double piles, the foundation response, and the load distribution among the piles have been investigated. The foundation response was evaluated considering horizontal load, top displacement, top moment and rotation, and the initial stiffness of the pile-soil system. From the obtained response, it is recommended that the foundation system is superior to the relatively conventional system with single piles at the corners. The results show that the piles under lateral tensile loads apparently withstand less load than the lateral compressive load. Furthermore, the condition of the piles in lateral tension is of greater importance. As the main pile, it carries significantly fewer loads at the end of the pile, which indicates that double piles with one replacement pile at a length of 1/2 and a distance of S=5D, 6D provide a better response. Where L is the embedded length of the pile in the conventional system and D is the pile diameter.
Otomatik Özet:
A numerical parametric study was conducted to determine the effects of pile spacing and pile length on their behavior with the protected system under a combination of uniform loads in highly compacted sand.
Before the analysis, the numerical model was validated in the context of testing single and double piles; generally, the contribution of the near-field space of double piles, the foundation response, and the load distribution among the piles have been investigated.
The foundation response was evaluated considering horizontal load, top displacement, top moment and rotation, and the initial stiffness of the soil-pile system.
This refers to the studies of Dohrcupov and Barbosa, which indicated that pile damage during installation in gypsum was estimated, and the destructive characteristics of the gypsum around the pile, the response of the foundation system under periodic loads, a result of oscillation tests on gypsum obtained from the Vikinger site shows clearly that the shear stress decreases during oscillation.
The effects of load combinations on pile behavior are scarce in this literature, especially for offshore structures, and no study has yet been conducted on close pile spacing.
2- Numerical Model A 3D finite element model of a conventional jacket supporting pile and a jacket supported by a close-spacing double-pile foundation system has been developed and utilized within the scope of studies extensive parametric (5-7MW) offshore wind turbines.
Conclusion A numerical-based parametric study was conducted for a support system consisting of a jacket with close-spaced piles for large offshore wind energy converters in deep waters.